Microstrip circulator
4VO-28C
Technical conditions
The electromagnetic parameters of the ferrite microstrip decoupler at acceptance and delivery under normal environmental conditions must conform to table:
Frequency, GHz Insertion losses, dB Inverse losses, dB VSWR Temperature, °C Max input power, W
min max min max min max min max
16 17 0.60 0.70 20 30 1.30 -60 60 2
 
  1. Devices able to operate in the the working temperature range .
  2. Direct losses given relative to polycarbonate microstrip line with a characteristic impedance 50 ohms in open space.
  3. Geometry and dimensions of mounting camera is not defined .
  4. Device soldering temperature should not exceed the 150°C.
  5. Peak temperature on the adhesive seams should not exceed the 180°C.
  6. Matching transformers are optimized for microstrip line with permittivity ε=9.8.
  7. Optionally, optimization can be made on a coaxial transitions of the customer or microstrip line with lower permittivity.
Estimated price 20 $ *

If you have technical or commercial questions, contact us by email mwfcomponent@gmail.com

 
28C figure
 
Figure 1. Overall and mounting dimensions.
 
4VO-28C
circulator direct design version
4VO-28C-1
circulator reversed design version
 
Figure 2. Design versions.